HP900 Series
HP900 UPS offers single/three phase double conversion online power protection with capacity of 1KVA-20KVA. The 32-bit microprocessor enables precise digital detection and control with high reliability. HP900 UPS features wide input voltage and frequency range based on advanced PFC technology. Intelligent battery management extends the battery life. LED/LCD display (optional) shows status of UPS directly. Clients may check operating status and historical data of UPS on PC via R232 at any time. Unattended and remote control management are available by SNMP and related software. It is ideal for data processing centers, server systems, communications systems and sophisticated equipment in telecommunications, finance, securities, insurance, taxation, transportation, medical, business and other fields. HP900 UPS is the perfect choice to keep your data safe and available.
■Advanced DSP digital control provides more stability and reliability;
■Digital PFC technology improves PF and reduces pollution to the grid;
■Reduce approximate 90% efficiency waste of power and your cost;
■Automatic protection of over charge, over discharge, under-voltage and over load;
■Configuration for N+X internal redundancy (6KVA-20KVA type) provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load;
■Cold start function enables you to power on the unit without any input power. It provides temporary emergency battery power when the utility power is out;
■Intelligent unattended function ensures that files are saved and the operating system is properly shutdown in the event of sustained power outage;
■Transient voltage surge suppression (TVSS) protection (1KVA-3KVA type);
■Emergency Power Off (EPO) function can shut down UPS in emergency;
■ABM technology maximizes battery performance, life, and reliability through smart and precise charging;
■Fault indicator immediately warns you of problems that may cause shocks and prevent the UPS from adequately suppressing surges with audible and light alarm;
■Advanced EMI technology compliant with EN50091-2 and IEC61000-4;
■LED/LCD display (optional) shows modes of operation, system parameters and alarms in text and mimics diagrams;
Model |
HP910H |
HP910S |
HP920H |
HP920S |
HP930H |
HP930S |
HP960H |
HP960S |
HP9010H |
HP9010S |
Power Capacity |
1KVA/900W |
2KVA/1800W |
3KVA/2700W |
6KVA/5400W |
10KVA/9000W |
|||||
Input |
||||||||||
Voltage |
110-288VAC (half load) 176-288VAC(full load) |
220/230/240VAC(110~300VAC) |
||||||||
Amperage |
4.8A(max) |
9.6A(max) |
14.4A(max) |
34A(max) |
57A(max) |
|||||
Frequency |
40~70Hz |
40~70Hz |
||||||||
Power Factor |
≥0.97 |
≥0.99 |
||||||||
Output |
||||||||||
Voltage |
220x(1±1%)VAC |
220/230/240x(1±1%)VAC |
||||||||
Frequency |
synchronized input (bypass mode) 50x (1 ± 0.1%) Hz(Online mode) 50x (1 ± 0.1%) Hz(Battery mode) |
synchronized input (bypass mode) 50x (1 ± 0.1%) Hz(Online mode) 50x (1 ± 0.1%) Hz(Battery mode) |
||||||||
Amperage |
4.3A |
8.6A |
13.5A |
27A |
45A |
|||||
Waveform |
<3% linear load, <5% nonlinear load |
<1% linear load, <5% nonlinear load |
||||||||
Load Capability |
105%~130% for 1min, over 150% switching to bypass after 30s |
105%~130% for 60min, over 130% switching to bypass after 1min |
||||||||
Load Crest Factor |
3:1(Max) |
|||||||||
Waveform |
Sine wave |
|||||||||
Power Factor |
0.9 |
0.9 |
||||||||
System |
||||||||||
Transfer Time |
0ms |
|||||||||
Efficiency |
≥90% |
|||||||||
Battery |
||||||||||
Type |
Sealed lead acid battery, maintenance free |
|||||||||
Voltage |
36VDC |
12V7AH*3PCS |
72VDC |
12V7AH*6PCS |
96VDC |
12V7AH*8PCS |
192VDC |
12V9AH*16PCS |
192VDC |
12V9AH*16PCS |
Panel Display |
||||||||||
LED |
Graphic display of UPS power indicator, inverter indicator, battery indicator, bypass indicating working state |
Graphic display of UPS power indicator, inverter indicator, battery indicator, bypass indicating working state |
||||||||
LCD |
Display UPS voltage, current, frequency, battery capacity, load capacity, failure information, operating mode, operating conditions |
Display UPS voltage, current, frequency, battery capacity, load capacity, failure information, operating mode, operating conditions |
||||||||
Control key |
FUNC、ON/OFF |
HOME、left and right、ON/OFF、ENTER |
||||||||
Interface |
RS232(standard), SNMP card(optional) |
|||||||||
Software |
1.UPS monitoring management; 2.remote control UPS; 3.historical data; 4.real-time audio alarm; 5.real-time detecting UPS status |
|||||||||
Protection |
||||||||||
Surge Protectiont |
YES |
|||||||||
DSL/ phone / fax surge protection |
RJ45 |
No |
||||||||
Short Circuit |
Cut off inverter and bypass output at the same time to protect the mains switch |
|||||||||
Temperature |
Built-in temperature switch to prevent over temperature, |
|||||||||
Working Environment |
||||||||||
Temperature |
0~40℃ |
|||||||||
Humidity |
0%~95% |
|||||||||
Elevation |
<1500m |
|||||||||
Standard |
||||||||||
Safety standard |
EN62040-1 |
|||||||||
EMC |
EN62040-2,EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6 |
|||||||||
Produce |
YD/T1095-2018 |
|||||||||
Physical Feature |
||||||||||
Size (W*D*H,mm) |
145*354*228 |
190*376*336 |
190*428*336 |
250*526 *480 |
250*526*640 |
250*526*480 |
250*526*640 |
|||
Net Weight (kg) |
6 |
12 |
10 |
21 |
11.5 |
25.6 |
18 |
57 |
20 |
65 |
Model |
3HP9010H |
3HP9015H |
3HP9020H |
Power Capacity |
10KVA |
15KVA |
20KVA |
Input |
|||
Cold start |
YES, default output frequency is 50Hz |
||
Voltage |
380/400/415VAC(190~518VAC) |
||
Frequency |
40~70HZ |
||
Phase |
3-in 1-out |
||
Power Factor |
≥0.95 |
||
Frequency adaptive |
Set up |
||
Output |
|||
Voltage |
220/230/240VAC |
||
Voltage Regulation |
± 1% |
||
Frequency |
synchronized input (bypass mode) 50x (1 ± 0.1%) Hz(Online mode) 50x (1 ± 0.1%) Hz(Battery mode) |
||
Waveform |
≤1% linear load; ≤5% nonlinear load |
||
Load Capability |
110%~130% for 60 minutes then witch to bypass, over 130% for 1 minutes then switch to bypass, over 150% for 0.5 minutes then switch to bypass, after 1 minutes cutting off the UPS output |
||
Load Crest Factor |
3:1 |
||
Waveform |
Sine wave |
||
Power Factor |
0.9 |
||
System |
|||
Mains/Battery Transfer Time |
0 ms |
||
Inverter cut bypass time |
0 ms |
||
Main Efficiency |
93.5 % |
||
Eco Efficiency |
98.00% |
||
Battery |
|||
Type |
Sealed lead acid battery, maintenance free |
||
Voltage |
192VDC、240VDC Configurable |
||
Panel Display |
|||
LED |
Graphic display of UPS power indicator, inverter indicator, battery indicator, bypass indicator, fault indication, UPS output indicating working state |
||
LCD |
Display UPS current, voltage, frequency, battery capacity, load capacity, historical records, fault information |
||
Control key |
HOME、left and right、ON/OFF、ENTER |
||
Communication Interface |
RS232(standard), SNMP card(optional) |
||
Software |
1.UPS monitoring management; 2.remote control; 3.historical data; 4.real-time voice alarm; 5.real-time detecting UPS status |
||
Protection |
|||
Surge Protection |
YES |
||
Short Circuit |
Cut off inverter and bypass output at the same time to protect the mains switch |
||
Temperature |
Built-in temperature switch to prevent temperature, |
||
Working Environment |
|||
Noise |
Load <70%, <50dB; load >70%, <65dB 1m |
||
Temperature |
0~40℃ |
||
Humidity |
0~95% |
||
Elevation |
<1000m |
||
Standard |
|||
Safety standard |
EN62040-1 |
||
EMC |
EN62040-2,EN61000-4-2,EN61000-4-3,EN61000-4-4,EN61000-4-5,EN61000-4-6 |
||
Produce |
YD/T1095-2018 |
||
Physical Feature |
|||
Size(W*D*H,mm) |
250*526*640 |
250*526*750 |
250*526*750 |
Net Weight(kg) |
25 |
33 |
33 |
Color |
Black |