·Description
GP800 UPS provides single phase power protection with capacities of 1KVA-20kVA. As the new generation online smart UPS which is based on digital technologies, GP800 UPS features the topological double conversion design which eliminates interferences, compatible with generators and zero transfer time when in emergency. The perfect protection circuit improved its stabilities and reliabilities. ABM technology protects batteries effectively. Clients may check the operating status and the historical data of UPS on PC via R232. Unattended and remote control management are available by SNMP and its related software. GP800 UPS provide you best protection for computers, servers, networks equipments in telecommunication, finance, insurance, government, transportation, medical labs and so on.
·Features
■Advanced 32-bit microprocessor improved the stability and reliability;
■SPWM technology, IGBT power module and output isolation transformer greatly reduced the interferences;
■Advanced EMI technology is compliant with EN50091-2 and IEC61000-4;
■Wide input voltage range of 304V-456V to extend the battery life;
■ABM technology maximizes battery performance, life, and reliability through smart and precise charging;
■Cold start function enables you to power on the unit without any input power. It provides temporary emergency battery power when the utility power is out;
■Self-diagnosis at startup reduced risks of system failure;
■Automatic protection of over charge, over discharge, under-voltage and over load;
■LCD displays current, voltage, frequency, fault information, environment, operating condition and loads status;
■LED displays supply modes, inverter supply, bypass supply and UPS emergency;
■Alarm indicators: Battery low voltage, overload, emergency;
■Standard RS232 interface and optional SNMP card enable its communication with PC;
Model |
GP801 |
GP802 |
GP803 |
GP804 |
GP806 |
GP808 |
GP810 |
GP815 |
GP820 |
UPS Capacity |
1KVA |
2KVA |
3KVA |
4KVA |
6KVA |
8KVA |
10KVA |
15KVA |
20KVA |
Input |
|||||||||
Voltage |
220V AC±25%/160~310V AC (AVR needed) |
||||||||
Frequency |
50(60)Hz±5% |
||||||||
Phase |
Single phase + GND |
||||||||
Max. Current |
6A |
12A |
18A |
24A |
34A |
45A |
56A |
82A |
110A |
Output |
|||||||||
Voltage |
220VAC |
||||||||
Voltage stability |
±1%( steady state) |
||||||||
Frequency |
50(60)Hz |
||||||||
Frequency Stability |
±0.5%( battery powered) |
||||||||
Wave Form |
sine wave |
||||||||
Power Factor |
≥0.8 |
||||||||
Distortion |
≤2% linear load |
||||||||
Transient Response |
voltage change ≤ 4% (100% loads throw or cut out) |
||||||||
Crest Factor |
3:1(Max) |
||||||||
Overload |
110~150% for 30sec then switch to bypass, load normal after recovery |
||||||||
System |
|||||||||
Control Mode |
SPWM |
||||||||
Efficiency |
>85% |
||||||||
Transfer Time |
0ms |
||||||||
Battery |
|||||||||
Type |
Sealed maintenance free lead acid battery |
||||||||
Voltage |
48VDC |
192VDC |
|||||||
Charge Time |
8hrs 90% |
||||||||
Interface |
|||||||||
LCD Display Screen |
display operation state of UPS, input, output voltage; input ,output frequency; battery voltage; output power (%); model of machine; load capacity; capacity; the temperature in the machine; working condition; working mode; fault state |
||||||||
Low Battery Light |
light up when battery voltage is low |
||||||||
Overload Light |
light up when overload |
||||||||
Failure Light |
light up when failure |
||||||||
LED Status Light |
instructions: electric model; battery model; inverter power supply; bypass; UPS anomaly |
||||||||
Software |
1. power state analysis 2. normal switching system of UPS 3. Monitoring UPS 4. implementation of UPS self diagnosis 5.automatic archives |
||||||||
Communication Interface |
the standard RS232 interface, optional SNMP card |
||||||||
Warning |
|||||||||
Outage |
buzzer call 1 times every 4 seconds |
||||||||
Electrical Anomaly |
buzzer call 1 times every 4 seconds, city power mode indicator flashing |
||||||||
Battery will run out |
buzzer call 1 times every 4 seconds, battery mode indicator flashing, low voltage light up |
||||||||
Overload |
overload indicator light up, the buzzer sounding |
||||||||
UPS Anomaly |
failure indicator light up, the buzzer sounding |
||||||||
Operational Environment |
|||||||||
Temperature |
0~40℃ |
||||||||
Humidity |
20~90% non-condensing |
||||||||
Altitude |
less than 1000m (elevation for each additional 500m, UPS output by reducing the amount of 5%) |
||||||||
Noise |
<58dB (1 meters distance box) |
||||||||
Protection |
|||||||||
Battery |
low battery shutdown, power recovery automatic restart, circuit breaker protection |
||||||||
Overload |
overload(120%-150%) 60s then switch to bypass, load normal after recovery |
||||||||
Temperature |
UPS internal temperature >85℃switch to bypass |
||||||||
Output Short Circuit |
current limiting, automatic shutdown, circuit breaker protection |
||||||||
UPS Anomaly |
automatic switch to bypass, power by the main power |
||||||||
Clutter Filter |
10~100KHz at 40dB; 100KHz~100MHz at 70dB |
||||||||
Protection Degree |
IP21 |
||||||||
Standard |
|||||||||
Safety Standard |
GB4943,EN62040-1 |
||||||||
EMC |
GB7260.2,EN62040-2,GB/T17626.2~5 |
||||||||
Produce |
YD/T1095-2018 |
||||||||
Physical Feature |
|||||||||
Net Weight (kg) |
55 |
58 |
60 |
63 |
75 |
96 |
105 |
120 |
125 |
Size (mm)(W*D*H) |
250*580*700 |
250*580*700 |
310*590*850 |
410*680*1020 |
Products shall be subject to any changes without additional notices. The pictures are for reference only. Please adhere to the original products in case of any mistake!