The Difference Between ATS and STS

發(fā)布時(shí)間: 2010/02/24 人氣 :25650

·The Difference Between ATS and  STS

STS (Static Transfer Switch) short static switch. STS is used in two separate switch between AC power supply, the first road after the failure of STS automatically switch to the second road to the load power supply, the second the words of STS path failure automatically switches to the first road to the load power. With the traditional automatic transfer switch ATS is different from the static transfer switches to provide fast load switching (typically 1 / 4 cycle), sophisticated electronic equipment to ensure uninterrupted work. Load re-conversion to the main input power is actually instantaneous ( 8ms). Suitable for UPS and the UPS, UPS and generators, UPS and the city, electricity, electricity and the electricity power supply such as an arbitrary two-way conversion UPS.

STS Static Transfer Switch mainly by the smart control panel, high-speed silicon, circuit breakers pose. The standard switching time is 8ms, will not cause IT class load power. Both on the load reliable power supply, while ensuring STS-phase switching in different security. STS Basic applications include electric power industry automation systems, petrochemical industry, power systems, computer and telecommunications centers, building automation and security systems, and other sensitive equipment against power failure.

ATS (Automatic Transfer Switch) Automatic Transfer Switch short. ATS is mainly used in emergency power supply system, will automatically load circuits from a power supply for access to another (standby) power supply switching equipment to ensure that critical load of a continuous, reliable operation. ATS mechanical structure to the implementation of contactors for switching components, switching function of intermediate relay or logic control modules to complete the secondary circuit control functions, drawback is that the main circuit contactor needs to loop a long-term secondary power, prone to temperature heating , contact bonding, coil burning and other failures. Furthermore, if a big load, the conversion time is relatively long, more than 100 milliseconds will cause the load power.
?
怀安县| 全椒县| 白山市| 伊金霍洛旗| 平乡县| 新干县| 介休市| 铜梁县| 天长市| 崇明县| 南昌市| 大竹县| 合阳县| 沿河| 册亨县| 曲阜市| 收藏| 夏津县| 运城市| 高密市| 阳江市| 庆阳市| 丹棱县| 洞口县| 南溪县| 高雄县| 徐水县| 光泽县| 平武县| 永清县| 温泉县| 鄂托克旗| 新巴尔虎右旗| 壤塘县| 普安县| 土默特右旗| 威远县| 曲沃县| 通许县| 萨嘎县| 肇州县|