在线观看的av网站|亚洲欧美精品午睡沙发|国内久久婷婷精品人双人|天天躁恨恨躁夜躁2024|成人3D动漫一区在线播放|香蕉精品视频一区二区三区|久久精品国产欧美日韩99热|亚洲色欲一区二区三区在线观看

December 22(Sunday) , 2024

Products / 產(chǎn)品資訊

username:
password:

AC Regulated Power Supply

Position:Home > Products > AC Regulated Power Supply > SBW-W Series Microcomputer Controlled Non-contact AC Stabilized Voltage Supply

SBW-W Series Microcomputer Controlled Non-contact AC Stabilized Voltage Supply

     

·Description

SBW-F series microcomputer controlled non-contact AC power supply is a new type voltage regulator that was developed by our company, combining imported technologies and domestic status quo. It adopts the advanced controlled silicon non-contact switch, microcomputer controlled AC voltage regulation technology and autotransformer.It has high efficient energy saving, fast adjustment, three-phase automatic balance, no abrasion of carbon brushes and mechanical failures. The controlled silicon adopts the non-contact mode with no interference for the state grid. The multi-route synchronous switchover greatly improved the adjusting time of voltage regulator. The advanced main loop and control system design effectively improve the dynamic stability and eliminate the common-mode current impact caused by the contact point switch and system damage caused by the overloads. The central control system adopts the SCM control with the LCD display, outstandingly shows the equipment’s safety, stability, and the friendly interface.

·Application fields

It is ideal for the unattended communication systems, broadcast systems, manufactures, power plants, computers, major medical equipments, elevator voltage and so on.

·Features

■Simultaneous switching through multi-channels, which greatly increases adjustment time of voltage regulator.

■SCR(silicon controlled rectifier) applies zero-crossing trigger, which exerts no influence on power grid.

Delayed output: after plugging in, it will delay 5-8 seconds to start the operation;

■It has strong instant over-capacity, dramatically enhancing the reliability of the system.
■When the regulator is on the fault or on the maintenance, the power supply can be automatically or manually connected;

■The RS232 and RS485 interfaces enable the remote control, remote communication and remote testing (optional);

■The powerful instantaneous overload ability greatly improves the stability of the system operation;
■When the state grid changes instantaneously or being stroked by lightning, the lightning conductor can provide the good surge protection (optional);

■The central controlling system applies single chip, equipped with LCD, which particularly manifests security, stability, energy conservancy and the humanization of human-computer interface.

Over/under voltage protection, short/wrong phase protection;
Automatic testing: when the hardware occurs the fault the microcomputer will automatically diagnosis to send the light alert signal;

■When the voltage of power grid is 4% more or less than the nominal voltage, voltage regulator can stop running automatically and power supply is at direct status.
■Main power double bypasses: when the hardware is out of order or the fuse sufferes from short circuit and then the voltage of electrical power network changes in 10% of rated voltage range the voltage regulator can automatically supply the power in the direct through status. In this situation, it can manually be switched to the main power directly through status by the” main power/voltage regulation” bypass switch;

■Automatic temperature-control: when the coil temperature of isolation transformer is over +70
, the auto-temperature controller can automatically start fans cooling function;

·Technical Specifications

 

Model
SBW-W
10KVA
SBW-W
15KVA
SBW-W
20KVA
SBW-W
30KVA
SBW-W
50KVA
SBW-W
100KVA
SBW-W
120KVA
Rated Power
10KVA
15KVA
20KVA
30KVA
50KVA
100KVA
120KVA
Input
Voltage
304V~456V, three-phase + N+E
Frequency
50~60Hz
Output
Phase
Three phase + N+E
Voltage
380V±(1-5%) adjustable
Voltage Regulation Mode
Steplessadjustment
System
Response Time
<0.04S
Waveform Distortion
≤0.1%
Efficiency
≥98%
Pressure-proofStrength
2000V 1minutes without breakdown
Insulation
Resistance
Coil-to-ground≥5MΩ(DC500V)
Filter
Performance
Frequency 0.1MHz-10GHz insertion loss,difference module 70-100dB,common mode 100dB
Voltage Regulation Mode
Manual and automatic two voltage regulation modes, no mechanical electrical shock voltage regulation mode
Environment
Temperature
-15℃~45℃
Humidity
0~90% ( non-condensing)
Elevation
No more than 2000 meters
Noise
<55dB
Protection
Protection
Function
over voltage, under voltage, over current, short phase, wrong phase, response function, lightning protection(optional)
Alarm Mute
When the fault occurs the regulator makes the voice and light alarm, it can be shut down manually
Bypass
When the regulator is on the fault or on the maintenance it has the power supply automatic or manualdirect through devices
Standby Input
Double power input: when one route power is down the regulator can manually/automatically (optional) switch to the other route standby power, when one standby power is back the regulator will automatically return to one route main power to supply the power (optional).
Multiple Input
According to the users’ power distribution system, to add the multiple input (optional)
Auto-power
Main power recovers from the power down it can choose to delay or resume the power supplying in order to the unattended watch, it can ensure the power supplying equipment that is not influenced by the high/low voltage impact.
anti-interference
According to the requirement of launch equipments’ power supplying or interference of self launch, it provides the reliable power supply which is equipped with the filter to prevent the radiated interference of launch equipment, it also configures the shielding protection case on the control circuit to avoid the voltage regulation to be out of control (optional).
Anti-surge performance
Spike inhibition input 4000V, pulse width 2us, output less than 20V; Spike inhibition input 4000V, pulse width 0.5us, output less than 2V.
Indication
Display (optional)
LCD displays the input/output voltage, current, dynamic description operation mode, high display brightness and uniform brightness without the flicker; LED digitally displays the input/output voltage, current, dynamic description operation mode, high display brightness and uniform brightness without the flicker.
Fault Indication
Under voltage, over voltage, over current, short phase, wrong phase, voice/light alarm
Computer Interface
Configured with the RS232 and RS485 interfaces to enhance the remote control, remote communication and remote testing functions (optional);
Digital Circuit
Microcomputer CPU control achieves the digitaltrue sampling to effectively overcome “out of control” and “distortion”performance.

 

 



Model
SBW-W
150KVA
SBW-W
180KVA
SBW-W
200KVA
SBW-W
225KVA
SBW-W
250KVA
SBW-W
320KVA
SBW-W
400KVA
SBW-F
500KVA
Rated Power
150KVA
180KVA
200KVA
225KVA
250KVA
320KVA
400KVA
500KVA
Input
Voltage
304V~456V, three-phase +N+E
Frequency
50~60Hz
Output
Phase
Three phase +N+E
Voltage
380V±(1-5%) adjustable
Voltage Regulation Mode
Stepless adjustment
System
Response Time
<0.04S
Waveform Distortion
≤0.1%
Efficiency
≥98%
Pressure-proof Strength
2000V 1minutes without breakdown
Insulation
Resistance
Coil-to-ground≥5MΩ(DC500V)
Filter
Performance
Frequency 0.1MHz-10GHz insertion loss,difference module 70-100dB,common mode 100dB
Voltage Regulation Mode
Manual and automatic two voltage regulation modes, no mechanical electrical shock voltage regulation mode
Environment
Temperature
-15℃~45℃
Humidity
0~90% ( non-condensing)
Elevation
No more than 2000 meters
Noise
<55dB
Protection
Protection
Function
Over voltage, under voltage, over current, short phase, wrong phase, response function, lightning protection (optional)
Alarm Mute
When the fault occurs the regulator makes the voice and light alarm, it can be shut down manually.
Bypass
When the regulator is on the fault or on the maintenance it has the power supply automatic or manual direct through devices;
Standby Input
Double power input: when one route power is down the regulator can manually/automatically (optional) switch to the other route standby power, when one standby power is back the regulator will automatically return to one route main power to supply the power (optional).
Multiple Input
According to the users’ power distribution system, to add the multiple input (optional)
Auto-power
Main power recovers from the power down it can choose to delay or resume the power supplying in order to the unattended watch, it can ensure the power supplying equipment that is not influenced by the high/low voltage impact.
Anti-interference
According to the requirement of launch equipments’ power supplying or interference of self launch, it provides the reliable power supply which is equipped with the filter to prevent the radiated interference of launch equipment, it also configures the shielding protection case on the control circuit to avoid the voltage regulation to be out of control (optional).
Anti-surge performance
Spike inhibition input 4000V, pulse width 2us, output less than 20V; Spike inhibition input 4000V, pulse width 0.5us, output less than 2V.
Indication
Display (optional)
LCD displays the input/output voltage, current, dynamic description operation mode, high display brightness and uniform brightness without the flicker; LED digitally displays the input/output voltage, current, dynamic description operation mode, high display brightness and uniform brightness without the flicker.
Fault Indication
Under voltage, over voltage, over current, short phase, wrong phase, voice/light alarm
Computer Interface
Configured with the RS232 and RS485 interfaces to enhance the remote control, remote communication and remote testing functions (optional);
Digital Circuit
Microcomputer CPU control achieves the digital true sampling to effectively overcome “out of control” and “distortion” performance.
Products shall be subject to any changes without additional notices. The pictures are for reference only. Please adhere to the original products in case of any mistake!
?