EPS Series

Position:Home > Products > EPS Series > CYS Series Three-phase Emergency Lighting Power Supply

 CYS Series Three-phase Emergency Lighting Power Supply

 

          

  

·Description

CYS three-phase EPS adopts the modern power electronic conversion, frequency conversion technology, with the latest intelligent IGBT module and CPU controlled digital products. It has a complete protection function, reliable and easy to maintain. It can provide the second line of emergency power for the important electrical equipment, fire-fighting devices and fire emergency lighting etc. As the increasing of the fire protection ability, the emergency light resources has become a necessary fire protection equipment.

·Application Field

It is ideal for the power supply or emergency lighting of various construction, medicine, traffic, financial, office, shopping mall, schools, dock, square and other places.

·Features

■Centralized power supply mode and doesn’t need any special lights;
■CPU control, pure sine wave output;
■Intelligent IGBT module guarantees the stable output balance;
■Smart monitor and firefighting via RS232;
■LCD, LED display, sound and light alarm, easy maintenance;
■No noise, no smoke, pollution-free, no fire hazards;
■Unattended automatic switching;
■Energy saving, basically no power consummation in normal times;

■Stable performance, safe and reliable and it has a long service life;

■Wide application. It can provide emergency lighting for personnel evacuating, fire protection and rescue and other emergency situations;

■Its comprehensive cost is low compared with the generator set and has a high cost performance.

 
·Technical Specifications
 
Model
CYS
2.2KW
CYS
3.7KW
CYS
5.5KW
CYS
7.5KW
CYS
11KW
CYS
15KW
CYS
18.5KW
CYS
22KW
Power
2.2KW
3.7KW
5.5KW
7.5KW
11KW
15KW
18.5KW
22KW
Input
Voltage
Three-phase 380V±25% Single-phase 220V±25%
Phase
Three-phase four-wire + PE
Frequency
50Hz±5%
Output
Voltage
In normal as same as the mains voltage    in emergency: 380V±3%
Frequency
In normal as same as the mains frequency   in emergency: 50Hz±0.5%
Waveform
Sine Wave
Output Routes
According to the design requirements, to make the output loop
Battery
Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leak proof
Rated Voltage
216VDC
DC324VDC
Charging Voltage
258VDC
368VDC
Charge Current
3A
7A
Charging Time
<20h
System
Transfer Time
<0.25s (according to the important occasion, it can be set the switch time to 0ms)
Emergency Time
90min (according to the requirement)
Overload
120% / 150% overloads can maintain 60 minutes / 5 seconds.
Protection
Under voltage, over current, short circuit protection
Noise
In normal without noise;  in emergency < 50dB (1m away)
Display
LED, LCD
Efficiency
In emergency power supplying: ≥92%  In normal: ≥99%
Environment
Humidity
0~90% ( non-condensing)
Temperature
-25℃~40℃
Elevation
≤2500m
Adapted Loads
Applicable to all kinds of the lighting loads
Physical Feature
Open-up and In-line
Single front door open, double-open back door, in/out lines of the bottom
Battery Cabinet
Batteries in the host cabinet
1
Size(mm)
(W*D*H)
750*410*1200
800*600*2200
Host EPS Weight(kg)
180
360
720
860
1030
230
260
280
Battery Weight (kg)
-
-
-
-
-
1120
1120
1580

 


 

Model
CYS
30KW
CYS
37KW
CYS
45KW
CYS
55KW
CYS
75KW
CYS
93KW
CYS
110KW
CYS
132KW
Power
30KW
37Kw
45KW
55KW
75KW
93KW
110KW
132KW
Input
Voltage
Three-phase 380V±25%/ Single-phase 220V±25%
Phase
Three-phase four-wire + PE
Frequency
50Hz±5%
Output
Voltage
In normal as same as the mains voltage;    in emergency: 380V±3%
Frequency
In normal as same as the mains frequency;  in emergency: 50Hz±0.5%
Waveform
Sine Wave
Output Routes
According to the design requirements, to make the output loop
Battery
Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leak proof
Charging Time
<20h
System
Transfer Time
<0.25s (according to the important occasion, it can be set the switch time to 0ms)
Emergency Time
90min (according to the requirement)
Overload
120% / 150% overloads can maintain 60 minutes / 5 seconds.
Protection
Under voltage, over current, short circuit protection
Noise
In normal without noise   in emergency < 50dB (1m away)
Display
LED、LCD
Efficiency
In emergency power supplying: ≥92%  In normal: ≥99%
Environment
Humidity
0~90% ( non-condensing)
Temperature
-25℃~40℃
Elevation
≤2500m
Adapted Loads
Applicable to all kinds of the lighting loads
Physical Feature
Open-up and In-line
Single front door open, double-open back door, in/out lines of the bottom
Battery Cabinet
2
3
4
5
6
Size(mm)
(W*D*H)
800*600*2200
1000*800*2200
Host EPS Weight(kg)
320
380
410
470
600
900
1000
1200
Battery Weight(kg)
1580
2240
3160
3160
4740
6320
6320
7900

 


 

Model
CYS
160KW
CYS
187KW
CYS
200KW
CYS
220KW
CYS
250KW
CYS
280KW
CYS
315KW
CYS
400KW
Power
160KW
187Kw
200KW
220KW
250KW
280KW
315KW
400KW
Input
Voltage
Three-phase 380V±25%/ Single-phase 220V±25%
Phase
Three-phase four-wire + PE
Frequency
50Hz±5%
Output
Voltage
In normal as same as the mains voltage;    in emergency: 380V±3%
Frequency
In normal as same as the mains frequency;  in emergency: 50Hz±0.5%
Waveform
Sine Wave
Output Routes
According to the design requirements, to make the output loop
Battery
Type
Maintenance-free sealed Lead-Acid battery with suspended electrolyte: leak proof
Charging Time
<20h
System
Transfer Time
<0.25s (according to the important occasion, it can be set the switch time to 0ms)
Emergency Time
90mins (according to the requirement)
Overload
120% / 150% overloads can maintain 60 minutes / 5 seconds.
Protection
Under voltage, over current, short circuit protection
Noise
In normal without noise;  in emergency <50dB (1m away)
Display
LED、LCD
Efficiency
In emergency power supplying: ≥92%  In normal: ≥99%
Environment
Humidity
0~90% ( non-condensing)
Temperature
-25℃~40℃
Elevation
≤2500m
Adapted Loads
Applicable to all kinds of the lighting loads
Physical Feature
Open-up and In-line
Single front door open, double-open back door, in/out lines of the bottom
Battery Cabinet
7
8
9
10
12
13
Size(mm)
(W*D*H)
1000*800*2200*2 sets
800*1200*2200
*2 sets
Host EPS Weight (kg)
180
360
720
860
1030
230
260
280
Battery Weight (kg)
-
-
-
-
-
1120
1120
1580

Products shall be subject to any changes without additional notices. The pictures are for reference only. Please adhere to the original products in case of any mistake!

?